Terminal Block Glossary: Terms for Drawings and Purchasing
Antong product selection reference · Updated 2 November 2026
A useful terminal specification uses the same terms in the drawing, quotation and inspection record. This glossary explains the terms that most often create ambiguity, especially when a catalogue name is mistaken for an electrical rating or an approval.
Connection and circuit terms
| Term | Meaning | Practical example or distinction |
|---|---|---|
| Terminal point | A location where a conductor is secured. | Two entry points can belong to one through connection. |
| Feed-through | A conductive path connecting an incoming and outgoing conductor. | It does not identify rail or panel mounting. |
| Screw connection | A clamp operated by a threaded fastener. | SP002 remains screw-operated despite its wire-protection spring. |
| Spring connection | A spring supplies the conductor-clamping force. | The operating method may use a tool, lever or direct insertion. |
| Push-in | A connection operated by inserting a permitted conductor into the entry. | Permitted bare or ferruled conductors depend on the product. |
| Pluggable | Two compatible terminal halves separate at a mating interface. | SP010/SP011 screw strips are not automatically PCB headers. |
| Pole / way / position | A counted part of the connection arrangement. | Check the circuit diagram: counted holes need not be isolated circuits. |
| Distribution block | A common connection serving several outputs. | UKK input and output openings can have different conductor ranges. |
Electrical and conductor terms
| Term | Meaning | Do not confuse it with |
|---|---|---|
| Rated current | A declared product current under specified conditions. | A current inferred only from the wire opening. |
| Rated voltage | A declared voltage with applicable product conditions. | Proof of suitability for every installation environment. |
| Wire cross-section | The conductive area, commonly stated in mm². | The outside diameter of the insulated cable. |
| AWG | A conductor-size system with its own discrete sizes. | An exact numerical equivalent to every metric size. |
| Conductor construction | Solid, stranded or flexible arrangement of the wire. | Cross-section alone. |
| Ferrule | A prepared end fitting crimped onto a conductor. | Permission to exceed the terminal’s approved wire range. |
| Strip length | Length of insulation removed for the specified connection. | Overall ferrule or cable length. |
| Derating | A reduction of usable capacity under stated conditions. | A universal percentage for every terminal. |
For example, SP004-01 lists a 2.5–4.0 mm² wire range and 3 A. Those are two separate catalogue fields; neither replaces the other.
Mechanical terms
| Term | Meaning | What to request |
|---|---|---|
| Pitch | Center spacing between identified repeating features. | The drawing showing the exact centers and tolerance. |
| Overall dimensions | The outer length, width and height. | Clearance for the body, wire and tool after assembly. |
| Thread size | A designation such as M2.5. | The separate permitted tightening torque. |
| Torque | A turning moment used to operate a fastener. | A model-specific value and unit, such as N·m. |
| DIN rail | A standardized mounting profile. | The required profile, dimensions and compatible foot. |
| End restraint | A component securing a row of rail-mounted devices. | A part compatible with the rail and terminal system. |
| Jumper / bridge | An accessory intentionally joining selected terminals. | The exact compatible series, positions and rating. |
Material tests and approval documents
| Term | What it describes | Boundary |
|---|---|---|
| PE, PP, PA6, PVC, PC | Housing material families. | A material name does not establish every operating limit. |
| Glow-wire test value | A defined test condition involving a heated wire. | 850°C is not an 850°C working-temperature rating. |
| UL 94 classification | Flammability behavior of a material under specified tests. | It is not approval of the complete terminal for every use. |
| IEC standard | A document specifying requirements or methods within its scope. | A reference to a standard is not itself a product certificate. |
| VDE / NF / UL approval evidence | A record with a defined issuer, product and scope. | Check the exact model and current status. |
| CE / RoHS declarations | Documentation addressing applicable conformity or substance requirements. | These terms are not interchangeable with one another or with a product safety mark. |
The IEC terminal-block standard and UL material-testing explanation describe different subjects. Keep the document type, edition and product scope explicit instead of listing all abbreviations as if they meant “certified.”
Turn the glossary into a usable order
A clear line item names the exact product and version, conductor arrangement, required ratings, mounting drawing, quantity and documents. Write missing values as requests for confirmation. Do not fill them by borrowing a figure from a similarly named series.
See the selection checklist for the sequence, the pitch guide for dimensional examples and the screw terminal guide for preparation and torque.
Product references
Model values above come from the linked Antong product pages. Confirm the ordered version and installation instructions before final selection.